Description

HCG2 standard PLC series provides 14-68 points mainframe and 8-40 points digital input/output modules, including the mainframe maximum input/output expansion up to 256/256 points.

Overview:

HCG2 standard PLC series provides 14-68 points mainframe and 8-40 points digital input/output modules, including the mainframe maximum input/output expansion up to 256/256 points. In addition, it can be used with analog input/output expansion module. temperature exoansion module, and weighing expansion module, with rich expansion and stable performance to meet a variety of applications.

Features:

1. Pulse control mode: lt can drive stepper/servo motor up to 12 axes.
2. lt supports single-phase high-speed counting to 12 channels and diferential high-speed counting input up to 6 channels: the maximum frequency is 200kHz.
3. With Ethernet function, support online monitoring, download program, support MODBUSTCP/IP communication, free protocol communication.
4. Using RS232 and RS485 dual-communication port, it both can realize HMl or PC communication, compatible with MODBUS ASCll and MODBUS RTU communication protocols.
5. Advanced saving technology in case of power-down, the program is permanently saved.
6. It can be expanded to 256 isolated input/output ports.
7. Program undergoes encryption processing, it is optional to upload or not for protecting the user’s intellectual property.
8. You can download by inserting a USB disk, download and monitor the program by using a dua-headed USB cable for faster communication, with a download rate of up to12Mbps.

Parameters:

Model Total I/O

points

Output

Mode

Output

Amount

Rated Current

Digital(high speed)

Input Points

Relay Output

Points

Analog input/output Analog input/output

Voltage Range

Communication

Interface

HCG2-14R-D 14 points Relay 2A 8(4) 6 RS232/RS485
HCG2-16R-D 16 points Relay 2A 8(4) 8 RS232/RS485
HCG2-1608R-D/A 24 points Relay 2A 16(-) 8 RS232/RS485/USB
HCG2-1410R-D/A 24 points Relay 2A 14(-) 10 RS232/RS485/USB
HCG2-32R-D/A 32 points Relay 2A 16(2) 16 RS232/RS485/USB
HCG2-40R-D/A 40 points Relay 2A 24(6) 16 RS232/RS485/USB
HCG2-48R-D/A 48 points Relay 2A 24(6) 24 RS232/RS485/USB
HCG2-48R6AO-D/A 48 points Relay 2A 24(6) 24 6 0-10V RS232/RS485/USB
HCG2-60R-D/A 60 points Relay 2A 36(6) 24 RS232/RS485/USB

Note:The maximum frequency of input is 200kh ① means the maximum frequency of high speed input is 50khz.

Note:D in the product model number means DC24V, A means AC100V-AC240V, and the default is DC24V if there is no suffix D or A for distinguishing purpose.

Electrical specification of input point

Specification HCG2-14R-D HCG2-16R-D HCG2-16TN(P)-D HCG2-14PN(P)-D HCG2-24PN(P)-D HCG2-32TN(P)/R-D/A HCG2-48TN(P)-6AB-D/A
Input Points X0~X3 X4~ X0~X1 X2~X7, X10~ X0~X13 X14~
Input Point Type Digital input
Input form DC(NPN/PNP)
Input Current DC24V, 5mA
Input Impedance 4.7KΩ
Maximum frequency 50kHz 10kHz 200kHz 10kHz 200kHz 10kHz
Response time Off→On <10μs <20μs <2.5μs <20μs <2.5μs <20μs
On→Off <20μs <50μs <5μs <50μs <5μs <50μs

 

Specification HCG2-

32PN(P)-D/A

HCG2-

32TN(P)L-D

HCG2-

48R-D/A

HCG2-

40TN(P)-D/A

HCG2-

40R-D/A

HCG2-

60PN(P)-D/A

HCG2-

60TN(P)-D/A

HCG2-

60R-D/A

HCG2-

48TN(P)-D

HCG2-

40TN(P)-C-D/A

HCG2-

48TN(P)6AO-D/A

HCG2-

40TN(P)2AO-D/A

HCG2-

40TN(P)-1AI1AO-D/A

HCG2-

48R6AO-D/A

Input Points X0~X5 X6~X7, X10~
Input Point Type Digital input
Input form DC(NPN/PNP)
Input Current DC24V, 5mA
Input Impedance 4.7KΩ
Maximum frequency 200kHz 10kHz
Response time Off→On <2.5μs <20μs
On→Off <5μs <50μs

Electrical specification of output point

Specification HCG2-14R-D HCG2-16R-D HCG2-32R-D HCG2-40R-D HCG2-48R-D HCG2-48R6AO-D HCG2-60R-D
Output Point Type Relay Output
Output Points All
Maximum load 2A AC250V/DC30V
Response time About 10ms