Description
Overview:
HV10 is the newest AC inverter with compact design from HNC Electric, thanks to advanced current vector control algorithm and newest hardware, HV10 has high stability and perfect motor control performance. Based on listening and understanding of customers’ requirement, HV10 supports full range of input voltage ( AC 120V / 220V / 380V / 460V and etc.) , complete functions for different countries and applications.
* Mini design housing suitable for micro automation such as packaging, labeling machine, conveyor belt etc.
* Double-line digital display, can display more content
* Detachable keyboard, external keyboard, convenient for customer debugging
* Powerful macro function, one-key setting, saving customer debugging time
* Built-in EMC C3 filter, stronger anti-electromagnetic interference ability
* Independent air duct design prevents dust from contacting the circuit board, better heat dissipation performance
* Installation back mounting system can insert the inverter directly into the rack
* Programmable DI/DO/AI/AO as well as RS485 Modbus RTU make easy communication with other devices
* Integrated PID function support most of water supply applications
* Integrated multi-speed function support most of texitile application
Features:
1. Mini design housing suitable for micro automation such as packaging, labeling machine, conveyor belt etc.
2. Double-line digital display, can display more content
3. Detachable keyboard, external keyboard, convenient for customer debugging
4. Powerful macro function, one-key setting, saving customer debugging time
5. Built-in EMC C3 filter, stronger anti-electromagnetic interference ability
6. Independent air duct design prevents dust from contacting the circuit board, better heat dissipation performance
7. Installation back mounting system can insert the inverter directly into the rack
8. Programmable DI/DO/AI/AO as well as RS485 Modbus RTU make easy communication with other devices
9. Upgrade I/O(NPN/PNP compatible) can meet more application requirement.
10. Integrated PID function support most of water supply applications
11. Integrated multi-speed function support most of texitile application
Parameters:
Model Definition:
Model | Input current (A) | Output current (A) | Adaptive motor
(KW) (HP) |
|
G1 input voltage range: Single-phase AC220V±15%, 50 / 60 Hz | ||||
HV10-R40G1-2 | 5.9 | 2.5 | 0.4 | 0.5 |
HV10-R75G1-2 | 8.3 | 4.2 | 0.75 | 1 |
HV10-1R5G1-2 | 14.1 | 7.5 | 1.5 | 2 |
HV10-2R2G1-2 | 24 | 10 | 2.2 | 3 |
G2 input voltage range: Three-phase AC220V±15%, 50 / 60 Hz | ||||
HV10-R40G2 | 4.1 | 2.5 | 0.4 | 0.5 |
HV10-R75G2 | 5.3 | 4.2 | 0.75 | 1 |
HV10-1R5G2 | 9 | 7.5 | 1.5 | 2 |
HV10-2R2G2 | 15 | 10 | 2.2 | 3 |
G3 input voltage range: Three-phase AC 380~440 (-15%~+10%), 50 / 60 Hz | ||||
HV10-R75G3 | 4.3 | 2.5 | 0.75 | 1 |
HV10-1R5G3 | 5.2 | 3.7 | 1.5 | 2 |
HV10-2R2G3 | 6.0 | 5.1 | 2.2 | 3 |
HV10-004G3 | 13.5 | 9.5 | 4.0 | 5 |
HV10-5R5G3 | 19.5 | 14 | 5.5 | 7.5 |
G4 input voltage range: Three-phase AC 460~480 (-15%~+10%), 50 / 60 Hz
|
||||
HV10-R75G4 | 4.1 | 2.5 | 0.75 | 1 |
HV10-1R5G4 | 4.9 | 3.7 | 1.5 | 2 |
HV10-2R2G4 | 5.7 | 5.0 | 2.2 | 3 |
HV10-004G4 | 11 | 8 | 4.0 | 5 |
HV10-5R5G4 | 15 | 10 | 5.5 | 7.5 |
Standard Specification:
Input | Rated voltage , Frequency | Three-phase (G3/G4 series) 380V-480V, 50/60HZ
Single&Three-phase (G1/G2 series) 220 V: 50/60 Hz |
||
Allowable range of voltage variation | Three-phase (G3 series) : AC 380~440 (-15%~+10%)
Three-phase (G4 series) : AC 460~480 (-15%~+10%) Single&Three-phase (G1/G2 series) : AC220V±15% |
|||
Output | Voltage | G1/G2 series; 0~220V, G3 series; 0~440 V, G4 series; 0~480 V | ||
Frequency | 0~999.9HZ | |||
Overload capacity | 110% long-term; 150% 1 minute; 180% 5 seconds | |||
Control mode | V/F control, Vector control | |||
Control characteristic | Frequency setting resolution | Analog input | 0.1% of the maximum output frequency | |
Digital settings | 0.1HZ | |||
Frequency accuracy | Analog input | Within 0.2% of the maximum output frequency | ||
Digital input | Within 0.01% of the set output frequency | |||
V/F control | V/F curve (voltage frequency characteristic) | Three ways: the first is linear torque characteristic curve, the second is square torque characteristic curve, and the third is user-set V/F curve | ||
Torque boost | Manual setting: 0.0 ~ 30.0% of rated output
Automatic lifting: automatically determine the boost torque according to the output current and motor parameters |
|||
Automatic current and voltage limiting | Whether in acceleration, deceleration or stable operation, the motor stator current and voltage can be automatically detected, which can be suppressed within the allowable range according to the unique algorithm to minimize the possibility of system fault tripping | |||
Sensorless vector control | voltage frequency characteristic | Automatically adjust output voltage-frequency ratio according to motor parameters and unique algorithm | ||
Torque characteristic | Starting torque:
100% rated torque at 5.0Hz (VF control) 150% rated torque at 0.5Hz (Vector control) |
|||
Current and voltage suppression | Full-range current closed-loop control, completely avoiding current impact, with perfect overcurrent and overvoltage suppression function | |||
Undervoltage suppression during operation | Especially for users with low grid voltage and frequent fluctuation of grid voltage, the system can maintain the longest possible operation time according to the unique algorithm and residual energy allocation strategy even in the range below the allowable voltage | |||
Typical function | Multi-stage speed operation | 7-stage programmable multi-stage speed control and multiple operation modes are optional. | ||
PID control
RS485 communication |
Built-in PID controller (preset frequency). Standard configuration RS485 communication function, multiple communication protocols can be selected, with linkage synchronous control function | |||
Frequency setting | Analog input | DC voltage 0 ~ 10 V, DC current 0 ~ 20 mA (upper and lower limits are optional) | ||
Digital input | Operation panel setting, RS485 interface setting, UP/DW terminal setting, and various combination settings with analog input can also be made. | |||
Output signal | Digital output | 1 OC output and 1 relay output (TA,TC), with up to 17 functions | ||
Analog output | 1 AO, the output range can be flexibly set between 0 ~ 20mA or 0 ~ 10V, which can realize the output such as set frequency and output frequency.etc | |||
Automatic voltage stabilizing operation | According to the needs, three modes can be selected: dynamic voltage stabilization, static voltage stabilization and non-voltage stabilization, so as to obtain the most stable operation effect | |||
Acceleration / deceleration time setting | 0.1S~999.9min can be set continuously | |||
Brake | Energy consumption braking | Energy consumption braking starting voltage, return difference voltage and energy consumption braking rate can be continuously adjusted | ||
DC brake | Starting frequency of DC braking during stop: 0.00 ~ [00.05] upper limit frequency
Braking time: 0.0 ~ 30.0s; Braking current: 0.0% ~ 50.0% of rated voltage of motor |
|||
Low noise operation | The carrier frequency is continuously adjustable from 2.0 kHz to 20.0 kHz to minimize the noise of the motor | |||
Counter | One internal counter is convenient for system integration | |||
Operating function | Upper and lower limit frequency setting, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency increment and decrement control, fault self-recovery operation, etc | |||
Display | Running status | Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, PID feedback , analog input and output, etc | ||
Alarm content | Record a number of operating parameters such as output frequency, set frequency, output current, output voltage, DC voltage and module temperature during the latest fault | |||
Protection function | Overcurrent, overvoltage, undervoltage, module failure, electronic thermal relay, overheating, short circuit, internal memory failure, etc. | |||
Environment | Ambient temperature | -10℃ ~ +40℃ (when the ambient temperature is 40℃ ~ 50℃, please use it at a reduced level) | ||
Ambient humidity | 5% ~ 95% RH, no water condensation | |||
Surrounding environment | Indoor (no direct sunlight, corrosion, flammable gas, oil mist, dust, etc.) | |||
Altitude | Derating for use above 1000 meters, every 1000 meters up derating 10% | |||
Structure | Protection grade | IP20 | ||
Cooling mode | Air-cooled with fan control |
Dimension:
Product Outline, Mounting Dimension, and Weight
Voltage
level |
Model | Outline construction and installation dimension(mm) | Weight
(kg) |
|||||
W | H1 | D | W1 | H2 | Mounting hole(d) | |||
1PH 220V | HV10−R40G1-2 | 60 | 160 | 134 | 78 | 170 | 4 | 0.9 |
HV10−R75G1-2 | ||||||||
HV10-1R5G1-2 | ||||||||
HV10−2R2G1-2 | ||||||||
3PH 220V | HV10−R40G2 | |||||||
HV10−R75G2 | ||||||||
HV10−1R5G2 | ||||||||
HV10-2G2G2 | ||||||||
3PH 380V | HV10−R40G3 | |||||||
HV10−R75G3 | ||||||||
HV10−1R5G3 | ||||||||
HV10−2R2G3 | ||||||||
HV10−004G3 | 78 | 200 | 152 | 95 | 212 | 4 | 1.3 | |
HV10−5R5G3 |
Download:
Series | Model | Download |
Frequency Inverter | HV10 Series Frequency Inverter Catalog-V2.1 | |
Frequency Inverter | HV10 Series Frequency Inverter User Manual-V8.1 |