Compare

Description

HV100W series is a general current vector control inverter integrated with the performance and features in a high degree, and high protection level (IP65). HV100W with industry-leading drive performance and functionality control, using unique current vect

Overview:

HV100W series is a general current vector control inverter integrated with the performance and features in a high degree, and high protection level (IP65). HV100W with industry-leading drive performance and functionality control, using unique current vector control algorithm can efficiently drive induction motor to achieve high accuracy, high torque and high-performance control.

Exquisite appearance design, reliable hardware structure,dual display, independent air duct, powerful functions, rich macro parameters .ect. These optimized designs make HV100W series an industry-leading product and bring tangible benefits to customers.

Customer success, Market Service!

HV100W in terms of performance and control are worthy of trust!

Features:

  1. Advanced motor control technology support Open loop vector control(SVC) and V/F control.
  2. High protection level (IP65) is designed for unprotected use in all outdoor and bad environments.
  3. Double-line digital display, can display more content
  4. Powerful macro function, one-key setting, saving customer debugging time
  5. Different input voltage(220V single phase/220V 3 phase/380V 3 phase/460V 3 phase).
  6. High starting torque characteristics and precise speed control.
  7. Upgrade I/O(NPN/PNP compatible) can meet more application requirement.
  8. Programmable DI/DO/AI/AO, and Modbus RTU make easy communication with other devices.
  9. Independent air duct design prevents dust from contacting the circuit board, better heat dissipation performance.

Parameters:

Model Definition:

Model Input current (A) Output current (A) Adaptive motor

(KW) (HP)

G1 input voltage range: Single-phase AC220V±15%, 50 / 60 Hz
HV100W-R75G1 8.2 4.5 0.75 1
HV100W-1R5G1 14 7 1.5 2
HV100W-2R2G1 23 10 2.2 3
G2 input voltage range: Three-phase AC220V±15%, 50 / 60 Hz
HV100W-R75G2 5 4.5 0.75 1
HV100W-1R5G2 7.8 7 1.5 2
HV100W-2R2G2 10.5 10 2.2 3
HV100W-004G2 16.6 16 3.7 5
HV100W-5R5G2 26 20 5.5 7.5
HV100W-7R5G2 35 30 7.5 10
HV100W-011G2 46.5 42 11 15
HV100W-015G2 62 55 15 20
HV100W-018G2 75 70 18.5 25
HV100W-022G2 85 80 22 30
HV100W-030G2 115 110 30 40
HV100W-037G2 135 130 37 50
HV100W-045G2 165 160 45 60
HV100W-055G2 210 200 55 75
G3 input voltage range: Three-phase AC 380~440 (-15%~+10%), 50 / 60 Hz
HV100W-R75G3 3.4 2.5 0.75 1
HV100W-1R5G3 5 3.7 1.5 2
HV100W-2R2G3 5.8 5 2.2 3
HV100W-004G3 10.5 9 4.0 5
HV100W-5R5G3 14.6 13 5.5 7.5
HV100W-7R5G3 20.5 17 7.5 10
HV100W-011G3 26 25 11 15
HV100W-015G3 35 32 15 20
HV100W-018G3 38.5 37 18.5 25
HV100W-022G3 46.5 45 22 30
HV100W-030G3 62 60 30 40
HV100W-037G3 80 75 37 50
HV100W-045G3 94 90 45 60
HV100W-055G3 128 110 55 75
HV100W-075G3 160 150 75 100
HV100W-093G3 190 176 93 125
HV100W-110G3 225 210 110 150
G4 input voltage range: Three-phase AC 460~480 (-15%~+10%), 50 / 60 Hz
HV100W-R75G4 3.4 2.5 0.75 1
HV100W-1R5G4 5 3.7 1.5 2
HV100W-2R2G4 5.8 5 2.2 3
HV100W-004G4 10.5 9 4.0 5
HV100W-5R5G4 14.6 13 5.5 7.5
HV100W-7R5G4 20.5 17 7.5 10
HV100W-011G4 26 25 11 15
HV100W-015G4 35 32 15 20
HV100W-018G4 38.5 37 18.5 25
HV100W-022G4 46.5 45 22 30
HV100W-030G4 62 60 30 40
HV100W-037G4 80 75 37 50
HV100W-045G4 94 90 45 60
HV100W-055G4 128 110 55 75
HV100W-075G4 160 150 75 100
HV100W-093G4 190 176 93 125
HV100W-110G4 225 210 110 150

Standard specifications:

Input Rating Voltage ,

Frequency

Three-phase (G3/G4 series) 380V-480V, 50/60HZ

Single&Three-phase (G1/G2 series)  220 V: 50/60 Hz

Allowable range

of voltage

Three-phase (G3 series) : AC 380~440 (-15%~+10%)

Three-phase (G4 series) : AC 460~480 (-15%~+10%)

Single&Three-phase (G1/G2 series) : AC220V±15%

Output Voltage G1/G2 series; 0~220V, G3 series; 0~440 V, G4 series; 0~480 V
Frequency Low frequency mode: 0 ~ 300 Hz; high frequency mode: 0 ~ 3000 Hz
Overload capacity G type machine: 110% long-term; 150% 1 minute ;200% 4 seconds

P type machine: 105% long-term ;120% 1 minute; 150% 1 second

Control mode V/F control, advanced V/F control, V/F separation control and PG-free current vector control
Control characteristic Frequency setting

Resolution

Analog end input 0.1% of the maximum output frequency
Digital settings 0.01Hz
Frequency accuracy Analog input Within 0.2% of the maximum output frequency
Digital input Set the output frequency within 0.01%
V/F control V/F curve (voltage frequency characteristic) The reference frequency can be set arbitrarily from 0.5 Hz to 3000 Hz, and the multi-point V/F curve can be set arbitrarily. You can also choose a variety of fixed curves such as constant torque, torque reduction 1, torque reduction 2 and square torque
Torque boost Manual setting: 0.0 ~ 30.0% of rated output

Automatic boost: automatically determine the boost torque according to the output current and motor parameters

Automatic current and voltage limiting Whether in acceleration, deceleration or stable operation, the motor stator current and voltage can be automatically detected, which can be suppressed within the allowable range according to the unique algorithm to minimize the possibility of system fault tripping
Control characteristic Sensorless vector control voltage frequency characteristic Automatically adjust output voltage-frequency ratio according to motor parameters and unique algorithm
Torque characteristic Starting torque:

150% rated torque at 3.0Hz (VF control)

150% rated torque at 1.0Hz (advanced VF control)

150% rated torque at 0.5Hz (without PG current vector control)

Running speed steady-state accuracy: ≤± 0.2% rated synchronous speed

Speed fluctuation: ≤± 0.5% rated synchronous speed

Torque response: ≤20ms (without PG current vector control)

Self-determination of motor parameters Without any restriction, the parameters can be automatically detected under static and dynamic conditions to obtain the best control effect
Current and voltage suppression Full-range current closed-loop control, completely avoiding current impact, with perfect overcurrent and overvoltage suppression function
Running

undervoltage suppression

Especially for users with low grid voltage and frequent fluctuation of grid voltage, the system can maintain the longest possible operation time according to the unique algorithm and residual energy allocation strategy even in the range below the allowable voltage
Typical function Multi speed and

Swing frequency operation

16-stage programmable multi-stage speed control and multiple operation modes are optional. Swing frequency operation: preset frequency and center frequency can be adjusted, and state memory and recovery after power failure
PID control

RS485 communication

Built-in PID controller (preset frequency). Standard configuration RS485 communication function, multiple communication protocols can be selected, with linkage synchronous control function
Frequency setting Analog input DC voltage 0 ~ 10 V, DC current 0 ~ 20 mA (upper and lower limits are optional)
Digital input keypad setting, RS485 interface setting, UP/DOWN terminal control, and various combination settings with analog input can also be made.
Output signal Digital output 2 Y-terminal open collector outputs and two programmable relay outputs (TA/TB/TC), with up to 61 functions
Analog output 2 analog signals are output, and the output range can be flexibly set between 0 ~ 20mA or 0 ~ 10V, which can realize the output of physical quantities such as set frequency and output frequency
Automatic voltage stabilizing operation According to the needs, three modes can be selected: dynamic voltage stabilization, static voltage stabilization and non-voltage stabilization, so as to obtain the most stable operation effect
Acceleration and deceleration

Time setting

0.1s~3600.0min can be set continuously, and S-type and linear mode can be selected
Brake Energy

consumption

Brake

Energy consumption braking starting voltage, return difference voltage and energy consumption braking rate can be continuously adjusted
Direct current

Brake

Starting frequency of DC braking during shutdown: 0.00 ~ [000.13] upper limit frequency

Braking time: 0.0 ~ 100.0 s; Braking current: 0.0% ~ 150.0% rated current

Magnetic flow

Brake

0 ~ 100 0: invalid
Low noise operation The carrier frequency is continuously adjustable from 1.0 kHz to 16.0 kHz to minimize the noise of the motor
Revolving speed tracking speed

Restart facility

It can realize the smooth restart and instantaneous stop restart of the motor in operation
Counter One internal counter is convenient for system integration
Operating function Upper and lower limit frequency setting, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency increment and decrement control, fault self-recovery operation, etc
Display keypad display Running

State

Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback amount, analog input and output, etc
Alarm

Content

The last six fault records, the record of six operation parameters such as output frequency, set frequency, output current, output voltage, DC voltage and module temperature during the last fault trip.
Protection function Over-current, over-voltage, under-voltage, module failure, electronic thermal relay, overheating, short circuit, input and output phase failure, abnormal tuning of motor parameters, internal memory failure, etc.
Environment Ambient temperature -10℃ ~+40℃ (the ambient temperature is 40℃ ~ 50℃, please use it at a reduced level)
Ambient humidity 5% ~ 95% RH, no water condensation
Surrounding environment Indoor (no direct sunlight, corrosion, flammable gas, oil mist, dust, etc.)
Altitude 1000 meters above the use of derating, every 1000 meters up derating 10%
Structure Protection grade IP65
Cooling mode Air-cooled with fan control
    Installation method Wall mounted, cabinet mounted

Dimension:

Model A

(mm)

B

(mm)

H

(mm)

W

(mm)

W1

(mm)

D

(mm)

Install Hole

(mm)

Installation Exterior
HV100W-R75G1/2 80 240 250 140 110 190 5
HV100W-1R5G1/2
HV100W-2R2G1/2
HV100W-R75G3/G4
HV100W-1R5G3/G4
HV100W-2R2G3/G4
HV100W-004G3/G4
HV100W-004G2 120 290 305 185 155 210 6
HV100W-5R5G2
HV100W-5R5G3/G4
HV100W-7R5G3/G4
HV100W-011G3/G4
HV100W-7R5G2 160 360 375 240 210 200 7
HV100W-011G2
HV100W-015G2
HV100W-015G3/G4
HV100W-018G3/G4
HV100W-022G3/G4
HV100W-030G3/G4
HV100W-018G2 200 482 500 300 270 230 7
HV100W-022G2
HV100W-037G3/G4
HV100W-045G3/G4
HV100W-030G2 245 520 540 345 315 290 9
HV100W-037G2
HV100W-055G3/G4
HV100W-075G3/G4
HV100W-045G2 270 555 575 380 350 320 9
HV100W-055G2
HV100W-093G3/G4
HV100W-110G3/G4

Download:

Series Model Download
Frequency Inverter HV100W Series Frequency Inverter User Manual-V7.3
Frequency Inverter HV100&HV100W Series Frequency Inverter Catalog-V2.0