Compare

Description

HRS series of soft starter is the latest development of HNC has an international leading technology of intelligent AC motor soft starter.

Overview:

HRS series of soft starter is the latest development of HNC has an international leading technology of intelligent AC motor soft starter. HHS Series Soft Starter uses the power electronic technology, the microprocessor technology and the modern control theory technology, has the present international advanced level the new starting equipment. This product can effectively limit the starting current of asynchronous motor, which can be widely used in fan, water pump, compressor and other transportation and heavy equipment, is the star delta conversion, autotransformer, magnetron step-down    start ideal replacement equipment.

HRS series of soft starter has excellent performance with the international high-end soft starter of the same, further strengthen the product reliability and environmental adaptability, humanization and professional design, can meet various application requirements.

Features:

1. Multi start mode:

The maximum output torque can be obtained by the voltage ramp mode. The maximum current can be obtained by the constant current soft starter mode, which can be applied to the load with large static friction force

2. High reliability:

The high performance microprocessor is used to process the signal in the control system, so as to avoid the excessive adjustment of the analog circuit in the past, so as to obtain excellent accuracy and execution speed

3. High performance:

*Programmable delay start mode, programmable interlocks control

*No sequence requirements for input power

*Starting time, parking time can be modified

*Dynamic fault memory function, easy to find the cause of the fault, up to ten faults can be recorded

4. Field bus full dynamic control monitoring starter, easy networking:

Bus type is MODBUS.

5. Variety of protection functions:

Protection against over voltage, under voltage, over temperature, phase loss, motor overload, etc.

6. English character display function:

LCD display a variety of operating parameters, programming and fault state with text prompts

7. Perfect humanized design:

*Beautiful appearance and reasonable structure

*Perfect function and simple operation

*Solid, reliable and compact

*The artistic design of industrial products

8. Reliable quality assurance:

*Computer simulation design

*STM patch production process

*Excellent electromagnetic compatibility

*High temperature aging, vibration test before the factory

9. Quick and thoughtful after-sales service:

*Reliable performance and quality lay the foundation for quality service

*Provide excellent and complete equipment design

*Timely and thoughtful use of consulting

*Continuously improve product performance according to user opinion

Parameters:

Selection table:

Three phase input & output

Model No.

Voltage

Power(Kw)

Current

(V)

AC220V

AC380V

AC460V

(A)

HRS-5R5-B-G3

400

5.5

5.5

11

HRS-7R5-B-G3

400

7.5

7.5

15

HRS-011-B-G3

400

5.5

11

11

23

HRS-015-B-G3

400

7.5

15

15

30

HRS-018-B-G3

400

18.5

18.5

37

HRS-022-B-G3

400

11

22

22

43

HRS-030-B-G3

400

15

30

30

60

HRS-037-B-G3

400

18.5

37

37

75

HRS-045-B-G3

400

22

45

45

90

HRS-055-B-G3

400

30

55

55

110

HRS-075-B-G3

400

37

75

75

150

HRS-090-B-G3

400

45

90

90

180

HRS-115-B-G3

400

55

110

110

230

HRS-132-B-G3

400

132

132

264

HRS-160-B-G3

400

75

160

160

320

HRS-185-B-G3

400

90

185

185

370

HRS-200-B-G3

400

110

200

200

400

HRS-250-B-G3

400

132

250

250

500

HRS-280-B-G3

400

280

280

560

HRS-320-B-G3

400

160

320

320

640

HRS-355-B-G3

400

185

355

355

710

HRS-400-B-G3

400

200

400

400

800

HRS-450-B-G3

400

450

450

900

HRS-500-B-G3

400

250

500

500

1000

HRS-630-B-G3

400

315

600

600

1200v

Dimension:

Outer dimension of soft starter

①Structure and dimension of product for HRS Series 5.5KW-55KW

  Model Rated power

(kw)

Rated current

(A)

Outer dimension(mm) Installation dimension(mm) Gross

weight

(kg)

W1 H1 D W2 H2 d
HRS-5R5-B-G3 5.5 11 146 272 160 133 247 M6 4.0
HRS-7R5-B-G3 7.5 15 146 272 160 133 247 M6 4.0
HRS-011-B-G3 11 23 146 272 160 133 247 M6 4.0
HRS-015-B-G3 15 30 146 272 160 133 247 M6 4.0
HRS-018-B-G3 18.5 37 146 272 160 133 247 M6 4.0
HRS-022-B-G3 22 45 146 272 160 133 247 M6 4.0
HRS-030-B-G3 30 60 146 272 160 133 247 M6 4.0
HRS-037-B-G3 37 75 146 272 160 133 247 M6 4.0
HRS-045-B-G3 45 90 146 272 160 133 247 M6 4.0
HRS-055-B-G3 55 110 146 272 160 133 247 M6 4.0

②Structural dimension of product for HRS Series 75KW or more

Model Rated power (kw) Rated current

(A)

Outer dimension(mm) Installation dimension(mm) Gross weight(kg)
W1 H1 D W2 H2 d
HRS-075-B-G3 75 150 260 435 200 225 360 M8 20
HRS-090-B-G3 90 180 260 435 200 225 360 M8 20
HRS-115-B-G3 115 230 260 435 200 225 360 M8 20
HRS-132-B-G3 132 260 260 435 200 225 360 M8 20
HRS-160-B-G3 160 320 260 435 200 225 360 M8 20
HRS-185-B-G3 185 370 260 435 200 225 360 M8 20
HRS-200-B-G3 200 400 260 435 200 225 360 M8 20
HRS-220-B-G3 220 440 260 435 200 225 360 M8 20
HRS-250-B-G3 250 500 290 460 200 255 390 M8 30
HRS-280-B-G3 280 560 290 460 200 255 390 M8 30
HRS-320-B-G3 320 640 290 460 200 255 390 M8 30
HRS-400-B-G3 400 800 330 485 200 295 405 M8 36
HRS-450-B-G3 450 900 330 485 200 295 405 M8 36
HRS-500-B-G3 500 1000 330 485 200 295 405 M8 36
HRS-630-B-G3 630 1200 410 550 230 375 470 M8 56

Download:

Series Model Download
Frequency Inverter HRS Series High Performance Soft Starter