New HV100 series is a general current vector control inverter integrated with the performance and features in a high degree. HV100 with industry-leading drive performance and functionality control.

Overview:

New HV100 series is a general current vector control inverter integrated with the performance and features in a high degree. HV100 with industry-leading drive performance and functionality control, using unique current vector control algorithm can efficiently drive induction motor to achieve high accuracy, high torque and high-performance control.

Exquisite appearance design, reliable hardware structure, detachable keyboard, dual display, independent air duct, powerful functions, rich macro parameters .ect. These optimized designs make HV100 series an industry-leading product and bring tangible benefits to customers.

Customer success, Market Service!

HV100 in terms of performance and control are worthy of trust!

Features:

1. Advanced motor control technology support Open loop vector control(SVC) and V/F control.

2. Double-line digital display, can display more content

3. Powerful macro function, one-key setting, saving customer debugging time

4. Different input voltage(220V single phase/220V 3 phase/380V 3 phase/460V 3 phase).

5. High starting torque characteristics and precise speed control.

6. Suitable for all regions which have different grid and voltage.

7. Upgrade I/O(NPN/PNP compatible) can meet more application requirement.

8. Programmable DI/DO/AI/AO, and Modbus RTU make easy communication with other devices.

9. Detachable keyboard,support keyboard extension, convenient for customer debugging.

10. Independent air duct design prevents dust from contacting the circuit board, better heat dissipation performance.

11. Installation back mounting system can insert the inverter directly into the rack.

12.  Integrated multi-speed function support most of texitile application.

Parameters:

Model Definition:

Model Input current (A) Output current (A) Adaptive motor

(KW) (HP)

G1 input voltage range: Single-phase AC220V±15%, 50 / 60 Hz
HV100-R40G1 5.4 2.3 0.4 0.5
HV100-R75G1 8.2 4.0 0.75 1
HV100-1R5G1 14 7.0 1.5 2
HV100-2R2G1 23 9.6 2.2 3
G2 input voltage range: Three-phase AC220V±15%, 50 / 60 Hz
HV100-R40G2 3.4 2.1 0.4 0.5
HV100-R75G2 5 3.8    0.75 1
HV100-1R5G2 5.8 5.1           1.5 2
HV100-2R2G2 10.5 9           2.2 3
HV100-004G2 14.6 13           3.7 5
HV100-5R5G2 26 25           5.5 7.5
HV100-7R5G2 35 32           7.5 10
HV100-011G2 46.5 45           11 15
HV100-015G2 62 60           15 20
G3 input voltage range: Three-phase AC 380~440 (-15%~+10%), 50 / 60 Hz
HV100-R75G3 3.4 2.1 0.75 1
HV100-1R5G3 5 3.8 1.5 2
HV100-2R2G3 5.8 5.1 2.2 3
HV100-004G3 10.5 9 4.0 5
HV100-5R5G3 14.6 13 5.5 7.5
HV100-7R5G3 20.5 17 7.5 10
HV100-011G3 26 25 11 15
HV100-015G3 35 32 15 20
HV100-018G3 38.5 37 18.5 25
HV100-022G3 46.5 45 22 30
HV100-030G3 62 60 30 40

Standard specifications:

Input Rating Voltage ,

Frequency

Three-phase (G3/G4 series) 380V-480V, 50/60HZ

Single&Three-phase (G1/G2 series)  220 V: 50/60 Hz

Allowable range

of voltage

Three-phase (G3 series) : AC 380~440 (-15%~+10%)

Three-phase (G4 series) : AC 460~480 (-15%~+10%)

Single&Three-phase (G1/G2 series) : AC220V±15%

Output Voltage G1/G2 series; 0~220V, G3 series; 0~440 V, G4 series; 0~480 V
Frequency Low frequency mode: 0 ~ 300 Hz; high frequency mode: 0 ~ 3000 Hz
Overload capacity G type machine: 110% long-term; 150% 1 minute ;200% 4 seconds

P type machine: 105% long-term ;120% 1 minute; 150% 1 second

Control mode V/F control, advanced V/F control, V/F separation control and PG-free current vector control
Control characteristic Frequency setting

Resolution

Analog end input 0.1% of the maximum output frequency
Digital settings 0.01Hz
Frequency accuracy Analog input Within 0.2% of the maximum output frequency
Digital input Set the output frequency within 0.01%
V/F control V/F curve (voltage frequency characteristic) The reference frequency can be set arbitrarily from 0.5 Hz to 3000 Hz, and the multi-point V/F curve can be set arbitrarily. You can also choose a variety of fixed curves such as constant torque, torque reduction 1, torque reduction 2 and square torque
Torque boost Manual setting: 0.0 ~ 30.0% of rated output

Automatic boost: automatically determine the boost torque according to the output current and motor parameters

Automatic current and voltage limiting Whether in acceleration, deceleration or stable operation, the motor stator current and voltage can be automatically detected, which can be suppressed within the allowable range according to the unique algorithm to minimize the possibility of system fault tripping
Control characteristic Sensorless vector control voltage frequency characteristic Automatically adjust output voltage-frequency ratio according to motor parameters and unique algorithm
Torque characteristic Starting torque:

150% rated torque at 3.0Hz (VF control)

150% rated torque at 1.0Hz (advanced VF control)

150% rated torque at 0.5Hz (without PG current vector control)

Running speed steady-state accuracy: ≤± 0.2% rated synchronous speed

Speed fluctuation: ≤± 0.5% rated synchronous speed

Torque response: ≤20ms (without PG current vector control)

Self-determination of motor parameters Without any restriction, the parameters can be automatically detected under static and dynamic conditions to obtain the best control effect
Current and voltage suppression Full-range current closed-loop control, completely avoiding current impact, with perfect overcurrent and overvoltage suppression function
Running

undervoltage suppression

Especially for users with low grid voltage and frequent fluctuation of grid voltage, the system can maintain the longest possible operation time according to the unique algorithm and residual energy allocation strategy even in the range below the allowable voltage
Typical function Multi speed and

Swing frequency operation

16-stage programmable multi-stage speed control and multiple operation modes are optional. Swing frequency operation: preset frequency and center frequency can be adjusted, and state memory and recovery after power failure
PID control

RS485 communication

Built-in PID controller (preset frequency). Standard configuration RS485 communication function, multiple communication protocols can be selected, with linkage synchronous control function
Frequency setting Analog input DC voltage 0 ~ 10 V, DC current 0 ~ 20 mA (upper and lower limits are optional)
Digital input keypad setting, RS485 interface setting, UP/DOWN terminal control, and various combination settings with analog input can also be made.
Output signal Digital output 2 Y-terminal open collector outputs and two programmable relay outputs (TA/TB/TC), with up to 61 functions
Analog output 2 analog signals are output, and the output range can be flexibly set between 0 ~ 20mA or 0 ~ 10V, which can realize the output of physical quantities such as set frequency and output frequency
Automatic voltage stabilizing operation According to the needs, three modes can be selected: dynamic voltage stabilization, static voltage stabilization and non-voltage stabilization, so as to obtain the most stable operation effect
Acceleration and deceleration

Time setting

0.1s~3600.0min can be set continuously, and S-type and linear mode can be selected
Brake Energy

consumption

Brake

Energy consumption braking starting voltage, return difference voltage and energy consumption braking rate can be continuously adjusted
Direct current

Brake

Starting frequency of DC braking during shutdown: 0.00 ~ [000.13] upper limit frequency

Braking time: 0.0 ~ 100.0 s; Braking current: 0.0% ~ 150.0% rated current

Magnetic flow

Brake

0 ~ 100 0: invalid
Low noise operation The carrier frequency is continuously adjustable from 1.0 kHz to 16.0 kHz to minimize the noise of the motor
Revolving speed tracking speed

Restart facility

It can realize the smooth restart and instantaneous stop restart of the motor in operation
Counter One internal counter is convenient for system integration
Operating function Upper and lower limit frequency setting, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency increment and decrement control, fault self-recovery operation, etc

Dimension:

Product Outline, Mounting Dimension

Download:

Series Model Download
Frequency Inverter HV100 Series Frequency Inverter Catalog-V2.0
Frequency Inverter HV100 Series Frequency Inverter User Manual-V7.1